For ESCOs and federal primes

Lighting subcontractor prequalification checklist for ESCOs

Short answer: Ask for the safety record (the EMR from the insurance carrier, OSHA injury logs, and the rates they produce), insurance and bonding, licenses for the project’s location, and proof of who does the work: the sub’s own employees and registered apprentices, or brokered labor. Then check comparable past jobs with references, a sample closeout package your M&V plan can use, and readiness for federal-site clauses such as Davis-Bacon, badging, and E-Verify.

1. Safety record

Ask for three numbers, and know where each one comes from.

Metric What it measures Where it comes from
EMR (experience modification rate) The firm’s workers’ compensation claims experience, used in setting its premiums The insurance carrier or the state workers’ compensation agency
TRIR (total recordable incident rate) OSHA-recordable injuries and illnesses per 200,000 hours worked The OSHA 300 Log and payroll hours
DART rate Cases with days away, restricted work, or job transfer, per 200,000 hours worked Columns H and I of the OSHA 300-A summary, and payroll hours
  • EMR. OSHA describes it as “a term used in Workers Compensation systems in determining insurance premiums” and sends employers to their carrier or state workers’ compensation agency for the number. In Washington, for example, the Department of Labor & Industries assigns an experience factor greater than 1 when a business’s claim costs are likely to be higher than others in its risk classifications. Ask for the rate in writing from the carrier, not a number typed into a form.
  • OSHA logs. Under 29 CFR 1904.29, employers record injuries and illnesses on the OSHA 300 Log, summarize them on the 300-A, and fill out a 301 Incident Report for each case. The 300-A is posted from February 1 to April 30 (1904.32), and the records are kept for five years (1904.33). A company with 10 or fewer employees at all times during the last calendar year generally doesn’t have to keep them (1904.1), so a very small sub may have no logs. If so, ask for its hours and incident history instead.
  • Rates. The Bureau of Labor Statistics (BLS) computes an incidence rate as the number of injuries and illnesses times 200,000, divided by employee hours worked. The 200,000 hours represent 100 employees working 40 hours a week, 50 weeks a year. Work out the rates from the logs and hours yourself, then compare them with the industry rates BLS publishes.
  • Training cards. OSHA 10-hour and 30-hour cards come from OSHA’s Outreach Training Program, and the 30-hour class is aimed at supervisors and workers with some safety responsibility. OSHA calls the program voluntary and says none of its courses is a certification or fulfills an employer’s training duties under specific OSHA standards. Ask for the cards and for the training the job’s hazards call for.

2. Insurance and bonds

For work on a federal installation, FAR 28.307-2 sets minimums: workers’ compensation as state and federal law requires, employer’s liability of at least $100,000 (except in states with exclusive or monopolistic funds), general liability for bodily injury of at least $500,000 per occurrence, and auto liability of at least $200,000 per person and $500,000 per occurrence for bodily injury and $20,000 per occurrence for property damage. Those are floors: the contracting officer may require additional coverage and higher limits. The clause at FAR 52.228-5 has the prime flow these requirements down to any subcontract with work on a Government installation and keep a copy of each sub’s proof of insurance. DOE’s Generation 4 ESPC contract (section H.9) lists the same minimums, lets a task order require different coverage, and has the ESCO put the substance of that clause in all subcontracts. Ask for a certificate that shows the limits your contract requires.

On bonds, FAR 28.102-1 requires performance and payment bonds on any federal construction contract over $150,000. That’s the prime’s bond. Whether you require one from your lighting sub is your call; if you do, ask for a letter from the sub’s surety stating its bonding capacity.

3. Licensing

Electrical licensing varies by jurisdiction. Ask for the license that covers work where the project is, whose name it’s in, and which crew members hold journeyman or master licenses. Then check each one with the licensing board that issued it.

4. Who does the work

Ask whether the installers are the sub’s own employees, who the foreman will be, and whether any part of the install goes to another firm or a labor broker. On federal work it matters twice. Dollars below your first tier don’t count toward your Service-Disabled Veteran-Owned Small Business (SDVOSB) subcontracting goal (see SDVOSB subcontracting goals). And on Davis-Bacon work, 29 CFR 5.5 makes the prime responsible for submitting every subcontractor’s certified payrolls.

Then ask about apprentices. A Registered Apprenticeship program is “approved and validated by the U.S. Department of Labor or a State Apprenticeship Agency,” and pairs paid work with a mentor, classroom instruction, and a portable, nationally recognized credential. On Davis-Bacon work, 29 CFR 5.5(a)(4) lets apprentices be paid less than the predetermined rate only when each one is individually registered in a program registered with DOL’s Office of Apprenticeship or a State Apprenticeship Agency it recognizes. (A worker certified as eligible for probationary employment as an apprentice gets the same allowance for the first 90 days.) Ask for the program’s registration and each apprentice’s.

5. Past performance and references

  • Jobs like yours: similar fixture counts, similar buildings (occupied, around-the-clock, or secure), similar contract values.
  • The sub’s role on each job: prime, first-tier subcontractor, or lower.
  • A reference for each job by role (the owner’s project manager, the facility manager, or the contracting officer’s representative), and then make the calls.

6. M&V and closeout

FEMP’s M&V Guidelines 5.0 use lighting retrofits as the example for Option A: the key parameters are the power draws of the baseline and retrofit fixtures, with operating hours measured or estimated. The guidelines’ post-installation report includes a detailed list of installed equipment and any changes between the final proposal and as-built conditions, and verification methods include surveys, inspections, spot measurements, and short-term metering.

The installer’s closeout feeds that report, so ask for a sample closeout package from a past job: as-installed counts by space, before-and-after fixture wattages, red-line drawings, photos, and disposal records. Ask whether the sub can support the spot measurements your M&V plan calls for. For disposal, EPA’s universal waste rules count fluorescent, high-intensity discharge, mercury vapor, high-pressure sodium, and metal halide lamps among common universal waste lamps (40 CFR 273.9). Ask how the sub handles lamps and ballasts and what certificates you’ll get.

7. Federal-site requirements

On a federal ESPC, the prime contract decides what flows down. DOE’s Generation 4 generic contract incorporates, among others:

  • FAR 52.222-6, Construction Wage Rate Requirements, and 52.222-8, Payrolls and Basic Records. The Department of Labor says the Davis-Bacon and Related Acts cover contracts over $2,000 for construction, alteration, or repair, apply to contractors and subcontractors, and require no less than the locally prevailing wages and fringe benefits. Under 29 CFR 5.5, certified payrolls go in weekly.
  • FAR 52.204-9, Personal Identity Verification of Contractor Personnel, which flows down to subcontracts whose employees need routine physical access to a federally controlled facility.
  • FAR 52.222-54, Employment Eligibility Verification (E-Verify), which flows down to subcontracts for services or construction worth more than $3,500 with work performed in the United States.
  • FAR 52.236-13, Accident Prevention, and under section H.10, the ordering agency’s own safety program requirements.

Ask whether the sub has run certified payroll, badged crews onto a federal site, and used E-Verify.

How we work with ESCOs

  • Self-performed. Every install is done by our own electrical crews, not layers of subcontractors. Our field personnel are licensed electricians and apprentices in DOL-approved apprenticeship programs.
  • SDVOSB. We’re an SBA-certified SDVOSB.
  • Case studies. At the University of Kentucky, 14 occupied student-housing buildings, with M&V per FEMP using IPMVP Options A and C. At the VA’s Troy Bowling Campus in Lexington, an active hospital, phased with the VA’s contracting officer’s representative. At the Boone National Guard Army Aviation Support Facility in Frankfort, an active Army aviation maintenance hangar, with zero disruption to flight operations. See the projects.

See how we work with ESCOs, or send us a project to price.

Sources

  1. OSHA FAQ: What does EMR stand for and where can I get it?U.S. Department of Labor, Occupational Safety and Health Administration, Accessed November 20, 2026
  2. Experience ratingWashington State Department of Labor & Industries, Accessed November 20, 2026
  3. 29 CFR 1904.29, FormsElectronic Code of Federal Regulations, Current as of November 18, 2026
  4. 29 CFR 1904.32, Annual summaryElectronic Code of Federal Regulations, Current as of November 18, 2026
  5. 29 CFR 1904.33, Retention and updatingElectronic Code of Federal Regulations, Current as of November 18, 2026
  6. 29 CFR 1904.1, Partial exemption for employers with 10 or fewer employeesElectronic Code of Federal Regulations, Current as of November 18, 2026
  7. How To Compute Your Firm’s Incidence Rate for Safety ManagementU.S. Bureau of Labor Statistics, Last modified March 10, 2025
  8. Injuries, Illnesses, and Fatalities (IIF) homeU.S. Bureau of Labor Statistics, Accessed November 20, 2026
  9. Outreach Training ProgramU.S. Department of Labor, Occupational Safety and Health Administration, Accessed November 20, 2026
  10. FAR 28.307-2, LiabilityAcquisition.gov (FAR Council), FAC 2026-01, effective March 13, 2026
  11. FAR 28.306, Insurance under fixed-price contractsAcquisition.gov (FAR Council), FAC 2026-01, effective March 13, 2026
  12. FAR 52.228-5, Insurance—Work on a Government Installation (Jan 1997)Acquisition.gov (FAR Council), FAC 2026-01, effective March 13, 2026
  13. FAR 28.102-1, Performance and payment bonds and alternative payment protections for construction contracts (General)Acquisition.gov (FAR Council), FAC 2026-01, effective March 13, 2026
  14. 2023 DOE IDIQ ESPC, Generation 4 Generic Contract (sections H.9, H.10, and I.1)U.S. Department of Energy, August 3, 2023
  15. Registered Apprenticeship ProgramU.S. Department of Labor, Apprenticeship.gov, Accessed November 20, 2026
  16. 29 CFR 5.5, Contract provisions and related mattersElectronic Code of Federal Regulations, Current as of November 18, 2026
  17. Davis-Bacon and Related ActsU.S. Department of Labor, Wage and Hour Division, Accessed November 20, 2026
  18. FAR 52.204-9, Personal Identity Verification of Contractor Personnel (Jan 2011)Acquisition.gov (FAR Council), FAC 2026-01, effective March 13, 2026
  19. FAR 52.222-54, Employment Eligibility Verification (Jan 2025)Acquisition.gov (FAR Council), FAC 2026-01, effective March 13, 2026
  20. M&V Guidelines: Measurement and Verification for Performance-Based Contracts, Version 5.0U.S. Department of Energy, Federal Energy Management Program, September 2024
  21. 40 CFR 273.9, Definitions (universal waste lamp)Electronic Code of Federal Regulations, Current as of November 18, 2026

Send us your next fixture schedule.

We’ll price the labor line by line within 3–5 business days, with our own crews on the job.