Service

Free lighting audits for commercial buildings

We audit most buildings’ lighting for free. We count every fixture, work out the light each space needs, and give you a savings model and a rebate estimate, so you see the cost, the savings, and the incentives before you sign anything.

What a lighting audit is

A lighting audit is a walk-through of your building that records every fixture: what it is, where it is, how it’s mounted, what controls it, and how long it runs each day. From that, we work out what an LED retrofit would cost, what it would save, and which utility rebates apply. Ours is free for most buildings; buildings over 75,000 sq ft may not qualify. A full hospital, for example, can take two weeks to audit.

What we check

This is the checklist we work from:

  • Fixture types, lamps, and ballasts, counted space by space
  • Mounting heights and ceiling types
  • Hours of use, area by area
  • Existing controls: switches, sensors, timers, and any building automation system
  • Light levels now, measured in footcandles (the unit a light meter reads), and the levels each space needs
  • Your utility rates and the incentives your utility offers
  • Problems to fix along the way, such as failed fixtures, damaged housings, and areas that are too dark or too bright

What you get

  • A recommendation for each area. LED tubes, retrofit kits, or new fixtures, plus controls where they make sense, and why.
  • Photometric design where light levels matter. A model of the space showing the light each layout will put where people work, before you buy a fixture.
  • A savings model. The energy savings, the payback, and the rebate estimate, built from your building’s own fixture counts and hours, not generic percentages. Want a rough number first? Try the savings calculator.
  • The rebate paperwork. When you go ahead, we file it.

After the install, measured results

A savings model is a forecast. We also provide measurement and verification (M&V) support: measuring the results after the install to show what the retrofit actually saved. The International Performance Measurement and Verification Protocol (IPMVP) sets out the methods. Option A measures key values, such as fixture wattage, and Option C compares whole-building utility meter data before and after.

On the University of Kentucky student-housing program, we ran M&V per Federal Energy Management Program (FEMP) guidelines using IPMVP Options A and C. The measured savings came to 3,075,537 kWh a year, beating projections.

Where we’ve done it

For Greystar at the University of Kentucky in Lexington, we retrofitted 14 occupied student-housing buildings (2020–2022): about 35,500 lamps and fixtures across 2,589,708 sq ft. The program captured $157,601 in utility incentives, about 14% off the client’s cost, and the measured savings came to 3,075,537 kWh and $286,026 a year, beating projections.

Proof on record

Jobs we’ve done, with the numbers.

3,075,537kWh/yr

saved, beating projections

Student housing LED retrofit

University of Kentucky, for Greystar · Lexington, KY · 2020–2022

14 occupied buildings · 2,589,708 sq ft · about 35,500 lamps and fixtures

  • 319 kW demand reduction
  • $157,601 in utility incentives
  • Zero students displaced
See every project

Questions

Straight answers.

Is the lighting audit really free?

For most buildings, yes. We audit the lighting at no charge and give you the savings model and the rebate estimate, and you decide from there. Buildings over 75,000 sq ft may not qualify for a free audit. A full hospital, for example, can take two weeks to audit.

What do you need from us?

Access to the spaces, recent utility bills so the savings model uses your actual rates, and drawings if you have them.

What is photometric design?

A computer model of a space that predicts the light levels a fixture layout will produce. It shows whether a layout gives each area the light it needs before you buy anything.

Do you measure the savings after the install?

We provide M&V support. On one program we ran M&V per FEMP guidelines using IPMVP Options A and C, and the measured savings beat projections.

Find out what your building would save.

Start with a free lighting audit. We’ll show you the fixtures, the savings, and the rebates before you commit to anything.

Buildings over 75,000 sq ft may not qualify for a free audit. A full hospital, for example, can take two weeks to audit.