Savings calculator

LED retrofit savings calculator

Estimate what an LED lighting retrofit would save. The quick estimate works from your monthly electric bill. Fixture by fixture is for engineers and ESCOs working from a schedule. Every result is an estimate, and every assumption is cited below the calculator.

Calculator

Calculator mode
FixtureQtyExisting WLED WHours / yrRemove

Preset watts are system input watts (lamp plus ballast or driver) from the Illinois and Pennsylvania technical reference manuals. Exterior presets default to 4,303 dusk-to-dawn hours.

Assumptions and sources

How the estimate works.

Quick estimate. Your yearly bill divided by your rate gives your building’s yearly kWh. Lighting’s share of that comes from the federal survey of commercial buildings for your building type, and the LED cut comes from the deemed fixture wattages in a state technical reference manual: about 50% for fluorescent and about 64.5% for metal halide or high-pressure sodium (a mix uses 57%). Savings = yearly kWh × lighting share × LED cut.

Fixture by fixture. For each row, quantity × watts × hours ÷ 1,000 gives kWh a year, before and after. New controls cut the LED load by the percentage you enter.

CO₂. Each kWh saved avoids about 1.43 lb of CO₂, the EPA’s marginal (non-baseload) rate, which is the rate EPA points to for estimating emissions avoided by efficiency. Tons are short tons (2,000 lb).

Cost and payback. Installed cost varies too much by building to publish a sourced average, so we don’t guess. Enter a quote to see payback; the free audit gives you one.

AssumptionValueSource
Default electric rate$0.134/kWhU.S. Energy Information Administration, Electric Power Annual, Table 2.10 (2025 data, released Oct 2026)
Lighting share of electricityWarehouse 24.6% · Office 16.9% · School 17.2% · Hospital 15% · Retail 25.6% · Other 17.4%U.S. Energy Information Administration, 2018 Commercial Buildings Energy Consumption Survey, Table E3
Lighting share, manufacturing6.2%U.S. Energy Information Administration, 2022 Manufacturing Energy Consumption Survey, Table 5.1
LED cut and preset wattsFluorescent ~50%, HID ~64.5%Illinois Stakeholder Advisory Group, Illinois Statewide Technical Reference Manual v14.0 (effective Jan 2026), §4.5; Pennsylvania Public Utility Commission, 2026 Technical Reference Manual, Appendix C (fixture wattages)
Default hoursWarehouse 3,135 · Office 3,000 · School 3,038 · Hospital 7,616 · Retail 4,099 · Manufacturing 4,618 · Other 3,379Illinois Stakeholder Advisory Group, Illinois Statewide Technical Reference Manual v14.0 (effective Jan 2026), §4.5
CO₂ per kWh saved1.43 lbU.S. Environmental Protection Agency, eGRID2023, U.S. non-baseload CO₂ rate, adjusted for grid losses (1,372.5 lb/MWh ÷ (1 − 4.2%))
Networked controls49% averageNEEA and DesignLights Consortium, Energy Savings from Networked Lighting Control Systems (Report E20-316, 2020)

Get the real number for your building.

The free lighting audit counts your actual fixtures, hours, and rates, and finds the rebates that apply.

Buildings over 75,000 sq ft may not qualify for a free audit. A full hospital, for example, can take two weeks to audit.