For building owners and managers

How much does it cost to convert fluorescent to LED?

Short answer: It depends on what you replace and where. LED tubes usually cost the least to buy, retrofit kits more, and new fixtures the most, and labor, ceiling access, controls, after-hours work, disposal, and prevailing wage all move the price. Get a quote built from your own fixture count, subtract any utility rebate, and divide by the yearly savings to get your simple payback.

Why we don’t publish a typical price

You’ll find per-fixture and per-square-foot prices quoted online. We don’t quote one here. We haven’t found a current, authoritative public source for the installed cost of a commercial LED retrofit, and the real number swings with the factors below. What we can do is show you what drives the price, what offsets it, and how to judge a quote once you have one.

LED tubes, retrofit kits, or new fixtures

The U.S. Department of Energy (DOE) describes three ways to take a fluorescent fixture to LED:

  • LED tubes (TLEDs). Tubular LEDs that plug into the existing sockets in place of the fluorescent tubes.
  • Retrofit kits. The tubes and other fixture parts come out, and an LED kit goes into the existing housing.
  • New LED fixtures. The whole fixture, housing included, is replaced.

LED tubes come in three types. Type A runs on the fixture’s existing ballast, the device that controls current to fluorescent lamps. Type B is wired straight to line voltage, with the ballast disconnected. Type C runs from a separate LED driver. DOE’s 2024 guide compares all five options:

Option Equipment cost Labor cost Install time per fixture Potential energy savings vs. fluorescent
LED tube, Type A $ $ Under 5 minutes 20%
LED tube, Type B $ $$ 15 minutes 30–50%
LED tube, Type C $ $$ 15 minutes 30–50%
Retrofit kit $$ $$ 15–30 minutes 40–60%
New LED fixture $$–$$$ $$–$$$ 30 minutes 40–60%

The dollar signs are DOE’s relative ratings, not prices. The savings figures are estimates by Pacific Northwest National Laboratory, against a fluorescent baseline. Three points from the same guide matter for your budget:

  • The cheapest equipment isn’t always the cheapest job. DOE says labor for retrofit kits may approach or even exceed the labor for new fixtures, and that labor for tubes and kits is sometimes underestimated when an electrician has to rewire. An earlier DOE guide says labor costs can easily exceed the cost of materials.
  • Kits and new fixtures can be close. DOE says the price difference between them may not be substantial, so price both.
  • Type A tubes depend on the old ballast. DOE doesn’t recommend Type A tubes on a ballast that has been in use five years or longer. If your ballasts are that old, budget for new ones or choose another option.

What else moves the price

  • Fixture count and mix. Price scales with the number of fixtures, and a building with many fixture types takes more planning and staging than one with a few.
  • Mounting height. Fixtures you can reach from a ladder go fastest. Warehouse high-bays and gym lights need lifts, which add equipment cost and time.
  • Ceilings, and what’s above them. DOE notes that new fixtures will most likely require access above the ceiling, and it flags asbestos in the ceiling as a potential health hazard. It rates tubes and kits as good options where ceiling access is limited.
  • Controls. Sensors add equipment and labor, and they add savings (see the example below). DOE also notes that virtually all energy codes in use today require some form of lighting control beyond a room switch, and that, in general, any lighting alteration beyond replacing the lamps should meet shutoff requirements. Your local code decides; DOE’s Building Energy Codes Program lists each state’s.
  • After-hours work. If the building can’t give up space during the day, the work happens on nights and weekends. Shorter work windows and premium-time labor add cost, so ask how a quote prices them.
  • Disposal. EPA lists fluorescent lamps as a common example of universal waste, a category with its own federal handling rules. Ballasts made before July 2, 1979, may contain polychlorinated biphenyls (PCBs), EPA says, and DOE notes that the handling and disposal PCB ballasts require can add to installation costs.
  • Prevailing wage. The Davis-Bacon and Related Acts require locally prevailing wages and fringe benefits on federally funded or assisted contracts over $2,000 for the construction, alteration, or repair of public buildings or public works. Some states have their own prevailing-wage laws, each with its own dollar threshold.

What offsets the cost

Utility rebates. The DesignLights Consortium (DLC), a nonprofit, says its Qualified Products Lists are required by nearly 700 utility and energy efficiency programs for rebate eligibility. The DLC doesn’t set rebates; each program does. Before anything is ordered, confirm the products are on the list your program uses, and read the program’s rules. To find programs, DSIRE, a database of incentives for renewable energy and energy efficiency run by the N.C. Clean Energy Technology Center at N.C. State University, lists them by state. DOE’s Federal Energy Management Program (FEMP) points to it as a directory of utility incentive programs.

Each program sets its own amounts, so we won’t guess at yours. One data point from our own work: on our University of Kentucky student-housing program, utility incentives came to $157,601, about 14% off the client’s cost.

Lower maintenance. DOE notes that, compared with most fluorescent systems, LED systems can reduce maintenance and operation costs. If you know what relamping and ballast replacement cost you each year, count that too.

How to work out payback

Simple payback = (installed cost − rebates) ÷ annual savings.

That’s the simple payback in NIST Handbook 135, the life-cycle costing manual written for FEMP: the up-front investment divided by the yearly savings in energy, water, and operation, maintenance, and repair. NIST is clear about its limits. Simple payback ignores the time value of money and any savings after the payback date, so treat it as a rough screen, not the whole case.

A worked example

Take 100 recessed 2x4 troffers, each with three 32-watt T8 lamps, in a low-rise office. A troffer is a rectangular fixture that fits a dropped-ceiling grid, per DOE. The inputs come from the Illinois Technical Reference Manual (TRM), the basis Illinois uses to calculate the savings from its utilities’ efficiency programs, and from EIA:

  • Before: 84.5 W per fixture, the TRM’s figure for a 3-lamp 32 W T8 fixture.
  • After: 42.1 W, the TRM’s figure for an LED 2x4 troffer of 4,501–6,000 lumens.
  • Hours: 2,698 a year, the TRM’s figure for a low-rise office.
  • Rate: $0.1337 per kilowatt-hour (kWh), the 2025 U.S. commercial average from the U.S. Energy Information Administration (EIA).

The math:

  • Power saved: 100 × (84.5 − 42.1) W = 4,240 W, or 4.24 kW. That’s a 50% cut.
  • Energy saved: 4.24 kW × 2,698 hours = 11,440 kWh a year.
  • Dollars saved: 11,440 kWh × $0.1337 = about $1,529 a year.

So the simple payback is your net cost ÷ $1,529. Each $1,529 of net cost adds one year. Two things change the answer fast:

  • Hours. The same TRM uses 7,616 hours a year for a hospital, 2.8 times the low-rise office figure, so the same fixtures would save 2.8 times as much there.
  • Controls. The TRM gives interior occupancy sensors an energy savings factor of 24%. Applied to the LED load in this example (11,359 kWh a year), that’s about 2,726 kWh, or $364 a year more, to weigh against the cost of the sensors.

Your rate and hours will differ from these. The savings calculator runs the same math with your numbers.

How we can help

We’ll count your fixtures in a free lighting audit and give you a savings model and a rebate estimate built from your own counts, hours, and rates. Buildings over 75,000 sq ft may not qualify for a free audit. When you go ahead, we file the rebate paperwork, and our own licensed electricians and apprentices do the install.

Sources

  1. Upgrading Linear Fluorescent Fixtures to LED in Schools (PNNL-35622)U.S. Department of Energy, November 2024
  2. LED Retrofit Kits, TLEDs, and Lighting Controls: An Application Guide (DOE/EE 1544)U.S. Department of Energy, Federal Energy Management Program, March 2017
  3. 2026 Illinois Statewide Technical Reference Manual for Energy Efficiency, Version 14.0 (Vol. 1 and Vol. 2, §4.5)Illinois Stakeholder Advisory Group, filed with the Illinois Commerce Commission, September 19, 2025 (effective January 1, 2026)
  4. Electric Power Annual, Table 2.10, Average Price of Electricity to Ultimate Customers by End-Use Sector, by StateU.S. Energy Information Administration, October 21, 2026 (2025 data)
  5. NIST Handbook 135: Life Cycle Costing Manual for the Federal Energy Management ProgramNational Institute of Standards and Technology, September 2020
  6. DesignLights Consortium (DLC) Quick FactsDesignLights Consortium, Accessed November 20, 2026
  7. DSIREN.C. Clean Energy Technology Center, N.C. State University, Accessed November 20, 2026
  8. FEMP Facility Evaluation (Audit) DefinitionsU.S. Department of Energy, Federal Energy Management Program, December 2020
  9. PCBs in Fluorescent Light Ballasts (FLBs), fact sheet 530-F-20-005U.S. Environmental Protection Agency, July 2020
  10. Universal WasteU.S. Environmental Protection Agency, Updated September 18, 2026
  11. Davis-Bacon and Related ActsU.S. Department of Labor, Wage and Hour Division, Accessed November 20, 2026
  12. Dollar Threshold Amount for Contract Coverage Under State Prevailing Wage LawsU.S. Department of Labor, Wage and Hour Division, Revised January 1, 2023
  13. Building Energy Codes ProgramU.S. Department of Energy, Accessed November 20, 2026

Find out what your building would save.

Start with a free lighting audit. We’ll show you the fixtures, the savings, and the rebates before you commit to anything.

Buildings over 75,000 sq ft may not qualify for a free audit. A full hospital, for example, can take two weeks to audit.